Acetic Acid AR

CAS Number:64-19-7

Synonyms

  • Ethanoic Acid
  • Hydrogen Acetate
  • Methanecarboxylic Acid

Available in 2.5l units

Description

Acetic Acid AR – Identification of Product
Chemical Code: CHE-A1
Chemical Name: Acetic Acid Glacial
Chemical Grade: AR
Chemical Formula: C₂H₄O₂
Chemical Weight: 60.05 g/mol
CAS No: 64-19-7
Chemical Synonyms: Glacial Acetic Acid,
Acetic Acid

Hazards Identification
REACH No: 01-2119475328-30-XXXX
Signal Word: Danger
Supplemental Hazard Information:
Additional Hazard Information: This substance contains no components considered to be either persistent, bio-accumulative and toxic (PBT), or very persistent and very bio-accumulative (vPvB) at levels of 0.1% or higher.

Acetic Acid AR – Hazards statements
H226 – Flammable liquid and vapour.
H314 – Causes severe skin burns and eye damage.
Precautionary statements
P210 – Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P260 – Do not breathe dust/fume/gas/mist/vapours/spray.
P280 – Wear protective gloves/protective clothing/eye protection/face protection.
P303 + P361 + P353 – If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
P305 + P351 + P338 – If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P370 + P378 – In case of fire: Use dry powder or dry sand to extinguish.
Composition of Chemical
Chemical Formula: C₂H₄O₂
EC No 1272/2008: 01-2119475328-30-XXXX

First Aid Measures
General Advice: Consult a physician. Show this safety data sheet to the doctor in attendance.
If: Inhaled: If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
If: Skin Contact: Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. Consult a physician.
If: Eye Contac: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If: Swallowed: Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Important Symptoms: The most important known symptoms and effects are described in the labelling section.
Immediate Medical Attention: No Data Available

Firefighting Measures
Extinguishing Media: Use Water spray, Alcohol-resistant foam, Dry chemical or Carbon Dioxide.
Hazards Arising: No Data Available
Advice for Firefighters: Wear self-contained breathing apparatus for firefighting if necessary.
Info for Firefighting: Use water spray to cool unopened containers.
Accidental Release Measures
Personal Precautions: Use personal protective equipment.
Avoid breathing vapours, mist or gas.
Ensure adequate ventilation.
Remove all sources of ignition.
Evacuate personnel to safe areas.
Beware of vapours accumulating to form explosive concentrations.
Vapours can accumulate in low areas.
Enviromental Precautions: Prevent further leakage or spillage if safe to do so.
Do not let product enter drains.
Method for Containment: Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet-brushing and place in container for disposal according to local regulations.

Acetic Acid AR – Handling and Storage
Personal Precautions: Avoid inhalation of vapour or mist.
Keep away from sources of ignition – No smoking.
Take measures to prevent the build up of electrostatic charge.
Enviromental Precautions: Store in cool place.
Keep container tightly closed in a dry and well-ventilated place.
Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Moisture sensitive.

Acetic Acid AR – Exposure Controls | Personal Protection
Derived No Effect Level (DNEL)
Workers | Application Area | Exposure Routes | Health Effect | Value
Workers – Inhalation – Acute local effects – 25 mg/m³
Workers – Inhalation – Long-term local effects – 25 mg/m³
Workers – Skin contact – Long-term local effects – 10mg/kg BW/d
Consumers | Application Area | Exposure Routes | Health Effect | Value
Consumers – Inhalation – Acute local effects – 25 mg/m³
Consumers – Inhalation – Long-term local effects – 25 mg/m³
Predicted No Effect Concentration (PNEC)
Soil – 0.478 mg/Kg
Marine Water – 0.3058 mg/L
Fresh Water – 3.058 mg/L
Marine Sediment – 1.136 mg/Kg
Fresh Water Sediment – 11.36 mg/Kg
Sewage Treatment Plant – 85 mg/l
Aquatic Intermittent Release – 30.58 mg/l
Engineering Controls: Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Eye/Face Protection: Tightly fitting safety goggles. Face shield (8-inch minimum). Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166 (EU).
Skin Protection: Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching gloves outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU
Directive 89/686/EEC and the standard EN 374 derived from it.
Full contact –
Material: Bbutyl-rubber. Minimum layer thickness: 0,3 mm
Break through time: 480 min. Material tested: Butoject®
Splash contact –
Material: Nature latex/Chloroprene. Minimum layer thickness: 0,6 mm
Break through time: 32 min. Material tested: Lapren®
Data source: KCL GmbH, D-36124, Test method: EN374
If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
Body Protection: Complete suit protecting against chemicals. Flame retardant anti-static protective clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory Protection: Where risk assessment shows air-purifying respirators are appropriate use a full-face particle respirator with multi-purpose combination, type OV/AG (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Acetic Acid AR – Physical and Chemical Properties
Appearance: Clear, Colourless Liquid
Odour: Pungent
Odour Threshold: No Data Available
pH: 2.4 at 60.05 g/l
Melting Point: 16.2 °C (lit).
Boiling Point: 117 – 118 °C (lit).
Flash Point: 40.0 °C (closed cup)
Evaporation: No Data Available
Flammability: No Data Available
Upper/Lower Flammability or Explosive Limits: Upper explosion limit: 19.9% (V),
Lower explosion limit: 4% (V)
Vapour pressure: 73.3 hPa at 50.0°C,
15.2 hPa at 20.0°C
Vapour density: No Data Available
Relative density: 1,049 g/cm³ at 25°C
Water solubility: Completely miscible
Partition Coefficien: Log Pow: – 0.169
Auto-ignition Temperature: 485.0°C
Decomposition Temperature: No Data Available
Viscosity: No Data Available
Explosive properties: No Data Available
Oxidizing properties: No Data Available
Other Safety Info: Surface tension – 28.8 mN/m at 10.0°C

Reviews

There are no reviews yet.

Be the first to review “Acetic Acid AR”

Your email address will not be published. Required fields are marked *